<p>Thanks for the feedback.</p>
<p>When bischeck "stop working" it would be interesting to
understand if anything gets logged after it "stops" and also what
is logged when you do a restart - but I suggest you do a stop and
see what is logged before starting.</p>
<p>I would suggest that you change the log level in logback.xml for
all packages<br>
</p>
<p> <root level="INFO"><br>
<appender-ref ref="bischeck"/><br>
</root></p>
<p>To avoid duplicates you should also add the additivity="false" on
the other logger. Based on the standard logback.xml you can test
this in your test environment first, have not tested it my self,
and if it looks good deploy in in production according to your
specific customization of paths, etc.</p>
<p><br>
</p>
<p>logback.xml:<br>
</p>
<p><?xml version="1.0" encoding="UTF-8"?><br>
<br>
<configuration><br>
<jmxConfigurator /><br>
<appender name="bischeck"
class="ch.qos.logback.core.rolling.RollingFileAppender"><br>
<!--See also
<a class="moz-txt-link-freetext" href="http://logback.qos.ch/manual/appenders.html#RollingFileAppender">http://logback.qos.ch/manual/appenders.html#RollingFileAppender</a>--><br>
<File>/var/tmp/bischeck.log</File><br>
<encoder><br>
<pattern>%d{yyyy-MM-dd HH:mm:ss.SSS,Europe/Stockholm}
; %p ; %t ; %c ; %m%ex%n</pattern><br>
</encoder><br>
<br>
<rollingPolicy
class="ch.qos.logback.core.rolling.FixedWindowRollingPolicy"><br>
<maxIndex>3</maxIndex><br>
<FileNamePattern>/var/tmp/bischeck.log.%i</FileNamePattern><br>
</rollingPolicy><br>
<br>
<triggeringPolicy
class="ch.qos.logback.core.rolling.SizeBasedTriggeringPolicy"><br>
<MaxFileSize>1000KB</MaxFileSize><br>
</triggeringPolicy><br>
<br>
</appender><br>
<br>
<logger name="com.ingby" level="INFO" additivity="false"><br>
<appender-ref ref="bischeck"/><br>
</logger><br>
<br>
<br>
<logger
name="com.ingby.socbox.bischeck.configuration.CachePurgeJob"
level="DEBUG" additivity="false"><br>
<appender-ref ref="bischeck"/><br>
</logger><br>
<br>
<logger name="com.ingby.socbox.bischeck.cache.provider.redis"
level="DEBUG" additivity="false"><br>
<appender-ref ref="bischeck"/><br>
</logger><br>
<br>
<br>
<logger name="org.quartz" level="INFO" additivity="false"><br>
<appender-ref ref="bischeck"/><br>
</logger><br>
<br>
<root level="WARN"><br>
<appender-ref ref="bischeck"/><br>
</root><br>
<br>
</configuration><br>
</p>
<br>
The root section will secure that everything from any java packages
with WARN or ERROR is logged to the bischeck appender. <br>
Regards <br>
Anders<br>
<br>
<div class="moz-cite-prefix">On 07/25/2017 09:55 AM, Francesco
Giuseppe Toffoli wrote:<br>
</div>
<blockquote type="cite"
cite="mid:9f1a3b07-f520-e457-07af-f7b44ee42026@skylogic.it">
<meta http-equiv="Content-Type" content="text/html;
charset=iso-8859-15">
<p>Hi Anders,<br>
thanks for your reply. I'll answer you to the variuos questions:</p>
<p>(1) the java version is:</p>
<p> openjdk version "1.8.0_91"<br>
OpenJDK Runtime Environment (build 1.8.0_91-b14)<br>
OpenJDK 64-Bit Server VM (build 25.91-b14, mixed mode)<br>
</p>
and has not been updated recently. In our test environment, (where
the problem does not occur), the version is nearly the same
(1.8.0_121).<br>
The OS has not been updated, (CentOS release 6.6).<br>
<br>
(2) Redis has not been uptaded recently, (redis 2.8.23). At the
moment we have more or less 13.000 keys used.<br>
<br>
(3) We usually add checks, maybe weekly. The issue started to
occur some months ago, but it could happen that for 2 or 3 weeks
everything is ok, then we have several crashes in a week. I'm not
so inclined to give the guilt to some new checks, also because the
testing server is aligned to the production one. <br>
<br>
<br>
(5) Yes, the restart is done via '/etc/init.d/bischeckd restart'
and it solves the issue. Physical memory on the server is always
OK, i don't think to a jvm out of memory.<br>
<br>
In the Bischeck logs i didn't notice any error. However, at the
next crash i'll try have a deeper look at them.<br>
Could i have a look at some other logs maybe?<br>
<br>
Thanks,<br>
Francesco<br>
<br>
<br>
<br>
<br>
<br>
<div class="moz-cite-prefix">Il 24/07/2017 21:57, Anders Håål ha
scritto:<br>
</div>
<blockquote type="cite"
cite="mid:b685ee8b-e1ce-d943-b6e8-88545cdc8fca@ingby.com">
<meta http-equiv="Content-Type" content="text/html;
charset=iso-8859-15">
<p>Hi Giuseppe,</p>
<p>Sounds strange that it just stopped working after along time
of stability if not something has change:</p>
<p>- Anything change on the server you run bischeck on - OS, jdk
version, ......</p>
<p>- Update redis version? Change in configuration?</p>
<p>- Added any new bischeck check or changed something in the
configuration?<br>
</p>
<p>- Anything else you can think about that may have change?</p>
<p>When you say restarting is it the normal
/etc/init.d/bischeckd restart that fix the problem? The reason
I ask is that the script just do a kill with TERM signal. If
the jvm would be in a out of memory situation it may not be
enough, but you should have seen that in the log I guess. Sure
you do not have any ERROR or WARN entries in the log.</p>
<p>/Anders <br>
</p>
<p><br>
</p>
<br>
<div class="moz-cite-prefix">On 07/24/2017 02:14 PM, Francesco
Giuseppe Toffoli wrote:<br>
</div>
<blockquote type="cite"
cite="mid:95f4a4eb-1319-f8cb-acd0-1832252656d4@skylogic.it">
<meta http-equiv="content-type" content="text/html;
charset=iso-8859-15">
<p>Hi, <br>
we are experiencing a critical problem with Bischeck. It's a
couple of months it sometimes suddenly stops working: the
daemon /etc/init.d/bicheckd is running but no check results
are sent to Nagios. Restarting bischeck daemon fixes the
issue. <br>
Unfortunately we can't find any clue about the root cause on
bischeck logs, not even with DEBUG logging level enabled.
Redis database seems working properly and no increasing of
memory/cpu usage are reported on the server hosting bischeck
while the issue occurs. <br>
<br>
Do you have any suggestion on how to deeply investigate
this?</p>
<p>Regards,<br>
Francesco<br>
</p>
<div class="moz-signature">-- <br>
<meta http-equiv="content-type" content="text/html;
charset=iso-8859-15">
<title></title>
<p class="MsoNormal"><font color="#3333ff" size="-1">Francesco
Giuseppe Toffoli</font><span
style="font-size:10.0pt;font-family:"Times New
Roman","serif";color:black;mso-fareast-language:IT"><br>
Monitoring Engineer</span><span
style="mso-fareast-language:IT"></span></p>
<p class="MsoNormal"><span
style="font-size:10.0pt;font-family:"Times New
Roman","serif";mso-fareast-language:IT">GSE
Department</span><span style="mso-fareast-language:IT"></span>
</p>
<p class="MsoNormal"><span
style="font-size:10.0pt;font-family:"Times New
Roman","serif";mso-fareast-language:IT">Tel:
+39 0112738748<font size="-1">8</font></span><span
style="mso-fareast-language:IT"><o:p></o:p></span></p>
<span style="font-size:10.0pt;font-family:"Times New
Roman","serif";mso-fareast-language:IT">Mobile:
+39 349.800.60.35 <span style="color:black"><br>
Email: </span><u><span style="color:blue"><a
href="mailto:ftoffoli@skylogic.it"
moz-do-not-send="true">ftoffoli@skylogic.it</a></span></u></span><span
style="font-size:12.0pt;font-family:"Times New
Roman","serif";color:black;mso-fareast-language:IT"><br>
</span><b><span
style="font-size:12.0pt;font-family:"Times New
Roman","serif";color:#000099;mso-fareast-language:IT"><img
shrinktofit="true" id="_x0000_i1025"
src="imap://aha%40ingby%2Ecom@mail.messagingengine.com:993/fetch%3EUID%3E.INBOX.Drafts%3E5624?part=&filename=/home/franz/skylogic_logo.jpeg"
moz-do-not-send="true" border="0" width="190"
height="44"><br>
</span></b><b><span
style="font-size:10.0pt;font-family:"Times New
Roman","serif";color:#000099;mso-fareast-language:IT">Skylogic
S. p. A.</span></b><span
style="font-size:10.0pt;font-family:"Times New
Roman","serif";color:black;mso-fareast-language:IT"><br>
Strada Pianezza, 289<br>
10151 Torino, Italy </span> </div>
<br>
<br>
<br>
This message contains confidential information and is intended
only for the individual named. If you are not the named
addressee you should not disseminate, distribute or copy this
e-mail. Please notify the sender immediately by e-mail if you
have received this e-mail by mistake and delete this e-mail
from your system. E-mail transmission cannot be guaranteed to
be secure or error-free as information could be intercepted,
corrupted, lost, destroyed, arrive late or incomplete, or
contain viruses. The sender therefore does not accept
liability for any errors or omissions in the contents of this
message, which arise as a result of e-mail transmission. If
verification is required please request a hard-copy version.
Please note that any views or opinions presented in this email
are solely those of the author and do not necessarily
represent those of the Company.<br>
No employee or agent is authorized to conclude any binding
agreement on behalf of this Company nor, through this latter,
any of the Eutelsat Communication group with another party by
email without express written confirmation by a duly
authorized officer of the Company. The list of duly authorized
officers and the scope of their powers is published on the
Trade Register according to the national law of each
affiliate. <br>
</blockquote>
<br>
<pre class="moz-signature" cols="72">--
Ingby <a class="moz-txt-link-rfc2396E" href="http://www.ingby.com" moz-do-not-send="true"><http://www.ingby.com></a>
bischeck - dynamic and adaptive monitoring for Nagios <a class="moz-txt-link-rfc2396E" href="http://www.bischeck.org" moz-do-not-send="true"><http://www.bischeck.org></a>
<a class="moz-txt-link-abbreviated" href="mailto:anders.haal@ingby.com" moz-do-not-send="true">anders.haal@ingby.com</a><a class="moz-txt-link-rfc2396E" href="mailto:anders.haal@ingby.com" moz-do-not-send="true"><mailto:anders.haal@ingby.com></a>
Mjukvara genom ingenjörsmässig kreativitet och kompetens
Ingenjörsbyn
Box 531
101 30 Stockholm
Sweden
<a class="moz-txt-link-abbreviated" href="http://www.ingby.com" moz-do-not-send="true">www.ingby.com</a> <a class="moz-txt-link-rfc2396E" href="http://www.ingby.com/" moz-do-not-send="true"><http://www.ingby.com/></a>
Mobil: +46 70 575 35 46
Tele: +46 75 75 75 090
Fax: +46 75 75 75 091
</pre>
</blockquote>
<br>
<div class="moz-signature">-- <br>
<meta http-equiv="content-type" content="text/html;
charset=iso-8859-15">
<title></title>
<p class="MsoNormal"><font color="#3333ff" size="-1">Francesco
Giuseppe Toffoli</font><span
style="font-size:10.0pt;font-family:"Times New
Roman","serif";color:black;mso-fareast-language:IT"><br>
Monitoring Engineer</span><span
style="mso-fareast-language:IT"></span></p>
<p class="MsoNormal"><span
style="font-size:10.0pt;font-family:"Times New
Roman","serif";mso-fareast-language:IT">GSE
Department</span><span style="mso-fareast-language:IT"></span>
</p>
<p class="MsoNormal"><span
style="font-size:10.0pt;font-family:"Times New
Roman","serif";mso-fareast-language:IT">Tel:
+39 0112738748<font size="-1">8</font></span><span
style="mso-fareast-language:IT"><o:p></o:p></span></p>
<span style="font-size:10.0pt;font-family:"Times New
Roman","serif";mso-fareast-language:IT">Mobile:
+39 349.800.60.35 <span style="color:black"><br>
Email: </span><u><span style="color:blue"><a
href="mailto:ftoffoli@skylogic.it"
moz-do-not-send="true">ftoffoli@skylogic.it</a></span></u></span><span
style="font-size:12.0pt;font-family:"Times New
Roman","serif";color:black;mso-fareast-language:IT"><br>
</span><b><span style="font-size:12.0pt;font-family:"Times
New
Roman","serif";color:#000099;mso-fareast-language:IT"><img
shrinktofit="true" id="_x0000_i1025"
src="imap://aha%40ingby%2Ecom@mail.messagingengine.com:993/fetch%3EUID%3E.INBOX.Drafts%3E5624?part=&filename=/home/franz/skylogic_logo.jpeg"
moz-do-not-send="true" border="0" width="190" height="44"><br>
</span></b><b><span
style="font-size:10.0pt;font-family:"Times New
Roman","serif";color:#000099;mso-fareast-language:IT">Skylogic
S. p. A.</span></b><span
style="font-size:10.0pt;font-family:"Times New
Roman","serif";color:black;mso-fareast-language:IT"><br>
Strada Pianezza, 289<br>
10151 Torino, Italy </span> </div>
<br>
<br>
<br>
This message contains confidential information and is intended
only for the individual named. If you are not the named addressee
you should not disseminate, distribute or copy this e-mail. Please
notify the sender immediately by e-mail if you have received this
e-mail by mistake and delete this e-mail from your system. E-mail
transmission cannot be guaranteed to be secure or error-free as
information could be intercepted, corrupted, lost, destroyed,
arrive late or incomplete, or contain viruses. The sender
therefore does not accept liability for any errors or omissions in
the contents of this message, which arise as a result of e-mail
transmission. If verification is required please request a
hard-copy version. Please note that any views or opinions
presented in this email are solely those of the author and do not
necessarily represent those of the Company.<br>
No employee or agent is authorized to conclude any binding
agreement on behalf of this Company nor, through this latter, any
of the Eutelsat Communication group with another party by email
without express written confirmation by a duly authorized officer
of the Company. The list of duly authorized officers and the scope
of their powers is published on the Trade Register according to
the national law of each affiliate.
<br>
</blockquote>
<br>
<pre class="moz-signature" cols="72">--
Ingby <a class="moz-txt-link-rfc2396E" href="http://www.ingby.com"><http://www.ingby.com></a>
bischeck - dynamic and adaptive monitoring for Nagios <a class="moz-txt-link-rfc2396E" href="http://www.bischeck.org"><http://www.bischeck.org></a>
<a class="moz-txt-link-abbreviated" href="mailto:anders.haal@ingby.com">anders.haal@ingby.com</a><a class="moz-txt-link-rfc2396E" href="mailto:anders.haal@ingby.com"><mailto:anders.haal@ingby.com></a>
Mjukvara genom ingenjörsmässig kreativitet och kompetens