    <p>It was not clear in your answer, but have you restarted bischeck?
      You say you have restarted redis, but what about bischeck? <br>
    </p>
    <p>The redis config you restarted with, what did you configure
      differently?</p>
    <p>Anders <br>
    </p>
    <br>
    <div class="moz-cite-prefix">On 12/04/2017 11:12 AM, Francesco
      Giuseppe Toffoli wrote:<br>
    </div>
    <blockquote type="cite"
      cite="mid:c313d2e4-55fd-c1b8-2776-c011be3d4170@skylogic.it">
      <meta http-equiv="Content-Type" content="text/html;
        charset=iso-8859-15">
      Il 04/12/2017 10:43, Anders Håål ha scritto:<br>
      <blockquote type="cite"
        cite="mid:b7862bea-57da-ee27-c25b-9f0fd635c8e2@ingby.com">
        <meta http-equiv="Content-Type" content="text/html;
          charset=iso-8859-15">
        <p>Hi Francesco,<br>
          Redis memory will increase with the number of data points you
          collect and how long time you configured to keep them. So what
          was the memory before it started to grow? Was it steady on
          this level? How much is it growing? And not using the redis
          instance for anything else? (redis-cli info) <br>
        </p>
      </blockquote>
      <br>
      Hi Anders, thanks for your fast and really appreciated reply. The
      memory has also been stable, around 8/9% of total server available
      RAM. Now is around 61% and it grows more or less of +4% a day. So
      to be optimist we have a week before everything will crash :-(<br>
      Redis is used only by bischeck, except for a couple of script
      reading datas from it (but are very old and light scripts, so I
      exclude they can cause the issue).<br>
      Here below a screenshot of memory growth:<br>
      <img moz-do-not-send="false"
        src="cid:part1.6FCA90F6.4D330004@ingby.com" alt="asdasd"
        class="" width="844" height="260"><br>
      <br>
      <blockquote type="cite"
        cite="mid:b7862bea-57da-ee27-c25b-9f0fd635c8e2@ingby.com">
        <p> </p>
        <p>It's a good sign that your memory is the same between
          restarts, since that means that the redis persistence works.</p>
        <p>Have you restarted bischeck after the 20 Nov? <br>
        </p>
      </blockquote>
      Yes we have done some restarts, the last this morning to load a
      new redis configuration ( I set logs to debug level). <br>
      <br>
      <blockquote type="cite"
        cite="mid:b7862bea-57da-ee27-c25b-9f0fd635c8e2@ingby.com">
        <p> </p>
        <p>When it comes to the memory config in redis there are a
          number of strategies to manage memory, but in the bischeck
          setup redis is used as a data store and not as a cache, so you
          would not like to have any eviction polices. Setting
          max-memory will just make any write fail when redis is at its
          max-memory.<br>
          I think its safe to upgrade redis to a later version, but
          please try it first. Currently I run bischeck on 4.0.2 without
          problem. At the same time I do not think this is a redis bug.<br>
          To track what goes on in the your redis instance you can check
          with redis-cli. Every servicedefinition becomes its own list
          in redis. You can check the size (llen) of the list and see if
          its relates to your purge configuration. You can also read the
          first and last entities in the list to check the time stamp
          (lrange). Depending on the bischeck config you may also have
          additional lists for the servicedefinition for aggregrations.<br>
          /Anders<br>
        </p>
      </blockquote>
      <br>
      Ok, i'm writing a script to get, from Redis server, the lenght and
      the timestamp of every list writtend by Bischeck. I hope to find
      out if there is something growing too much.<br>
      I'll keep you updated.<br>
      Thanks for your support.<br>
      <br>
      Francesco<br>
      <br>
      <br>
      <br>
      <blockquote type="cite"
        cite="mid:b7862bea-57da-ee27-c25b-9f0fd635c8e2@ingby.com"> <br>
        <div class="moz-cite-prefix">On 12/04/2017 10:11 AM, Francesco
          Giuseppe Toffoli wrote:<br>
        </div>
        <blockquote type="cite"
          cite="mid:ced8dbf3-98fa-41a6-e92e-055739a62bed@skylogic.it">
          <meta http-equiv="content-type" content="text/html;
            charset=iso-8859-15">
          <p>Hi everybody,<br>
            since a coupe of weeks the memory used by Redis in
            increasing linearly, continuosly.<br>
            We are a bit worried as also after a Redis server restart
            the situation is the same (the RAM taken is equal before and
            after the restart).<br>
            I would exclude the issued has been caused by a
            configuration change, the issue started on 20 November at
            11:44PM when nobody was working on bischeck.<br>
            I'm enabling logs in order to see if there is something
            wrong.</p>
          <p>In the meanwhile does anyone have a suggestion on how to
            proceed?<br>
            Upgrading to Redis 4.0 (stable) can be done maintaining the
            retro-compatibility with Bischeck? (we have Redis 2.8.23)</p>
          <p><br>
          </p>
          <p>As a workaround I was thinking to enable the Redis option
            'maxmemory' with the 'maxmemory policy': about this last
            option, as we need all keys to be maintained on database,
            does anyone know as can be set? (I've read something about
            key eviction but i still don't have any clear idea).</p>
          <p><br>
          </p>
          <p>Regards,<br>
            Francesco<br>
          </p>
          <p><br>
          </p>
          <div class="moz-signature">-- <br>
            <meta http-equiv="content-type" content="text/html;
              charset=iso-8859-15">
            <title></title>
            <p class="MsoNormal"><font size="-1" color="#3333ff">Francesco
                Giuseppe Toffoli</font><span
                style="font-size:10.0pt;font-family:"Times New
                Roman","serif";color:black;mso-fareast-language:IT"><br>
                Monitoring Engineer</span><span
                style="mso-fareast-language:IT"></span></p>
            <p class="MsoNormal"><span
                style="font-size:10.0pt;font-family:"Times New
                Roman","serif";mso-fareast-language:IT">GSE
                Department</span><span style="mso-fareast-language:IT"></span>
            </p>
            <p class="MsoNormal"><span
                style="font-size:10.0pt;font-family:"Times New
                Roman","serif";mso-fareast-language:IT">Tel:
                +39 0112738748<font size="-1">8</font></span><span
                style="mso-fareast-language:IT"><o:p></o:p></span></p>
            <span style="font-size:10.0pt;font-family:"Times New
              Roman","serif";mso-fareast-language:IT">Mobile:
              +39 349.800.60.35 <span style="color:black"><br>
                Email: </span><u><span style="color:blue"><a
                    href="mailto:ftoffoli@skylogic.it"
                    moz-do-not-send="true">ftoffoli@skylogic.it</a></span></u></span><span
              style="font-size:12.0pt;font-family:"Times New
              Roman","serif";color:black;mso-fareast-language:IT"><br>
            </span><b><span
                style="font-size:12.0pt;font-family:"Times New
Roman","serif";color:#000099;mso-fareast-language:IT"><img
                  shrinktofit="true" id="_x0000_i1025"
src="imap://aha%40ingby%2Ecom@mail.messagingengine.com:993/fetch%3EUID%3E.INBOX.Drafts%3E5796?part=&filename=/home/franz/skylogic_logo.jpeg"
                  moz-do-not-send="true" width="190" border="0"
                  height="44"><br>
              </span></b><b><span
                style="font-size:10.0pt;font-family:"Times New
                Roman","serif";color:#000099;mso-fareast-language:IT">Skylogic
                S. p. A.</span></b><span
              style="font-size:10.0pt;font-family:"Times New
              Roman","serif";color:black;mso-fareast-language:IT"><br>
              Strada Pianezza, 289<br>
              10151 Torino, Italy </span> </div>
          <br>
          This message contains confidential information and is intended
          only for the individual named. If you are not the named
          addressee you should not disseminate, distribute or copy this
          e-mail. Please notify the sender immediately by e-mail if you
          have received this e-mail by mistake and delete this e-mail
          from your system. E-mail transmission cannot be guaranteed to
          be secure or error-free as information could be intercepted,
          corrupted, lost, destroyed, arrive late or incomplete, or
          contain viruses. The sender therefore does not accept
          liability for any errors or omissions in the contents of this
          message, which arise as a result of e-mail transmission. If
          verification is required please request a hard-copy version.
          Please note that any views or opinions presented in this email
          are solely those of the author and do not necessarily
          represent those of the Company.<br>
          No employee or agent is authorized to conclude any binding
          agreement on behalf of this Company nor, through thi s latter,
          any of the Eutelsat Communication group with another party by
          email without express written confirmation by a duly
          authorized officer of the Company. The list of duly authorized
          officers and the scope of their powers is published on the
          Trade Register according to the national law of each
          affiliate. <br>
        </blockquote>
        <br>
        <pre class="moz-signature" cols="72">-- 


Ingby <a class="moz-txt-link-rfc2396E" href="http://www.ingby.com" moz-do-not-send="true"><http://www.ingby.com></a>

bischeck - dynamic and adaptive monitoring for Nagios <a class="moz-txt-link-rfc2396E" href="http://www.bischeck.org" moz-do-not-send="true"><http://www.bischeck.org></a>

<a class="moz-txt-link-abbreviated" href="mailto:anders.haal@ingby.com" moz-do-not-send="true">anders.haal@ingby.com</a><a class="moz-txt-link-rfc2396E" href="mailto:anders.haal@ingby.com" moz-do-not-send="true"><mailto:anders.haal@ingby.com></a>

Mjukvara genom ingenjörsmässig kreativitet och kompetens

Ingenjörsbyn
Box 531
101 30 Stockholm
Sweden
<a class="moz-txt-link-abbreviated" href="http://www.ingby.com" moz-do-not-send="true">www.ingby.com</a> <a class="moz-txt-link-rfc2396E" href="http://www.ingby.com/" moz-do-not-send="true"><http://www.ingby.com/></a>
Mobil: +46 70 575 35 46
Tele: +46 75 75 75 090
Fax:  +46 75 75 75 091
</pre>
      </blockquote>
      <br>
      <div class="moz-signature">-- <br>
        <meta http-equiv="content-type" content="text/html;
          charset=iso-8859-15">
        <title></title>
        <p class="MsoNormal"><font size="-1" color="#3333ff">Francesco
            Giuseppe Toffoli</font><span
            style="font-size:10.0pt;font-family:"Times New
            Roman","serif";color:black;mso-fareast-language:IT"><br>
            Monitoring Engineer</span><span
            style="mso-fareast-language:IT"></span></p>
        <p class="MsoNormal"><span
            style="font-size:10.0pt;font-family:"Times New
            Roman","serif";mso-fareast-language:IT">GSE
            Department</span><span style="mso-fareast-language:IT"></span>
        </p>
        <p class="MsoNormal"><span
            style="font-size:10.0pt;font-family:"Times New
            Roman","serif";mso-fareast-language:IT">Tel:
            +39 0112738748<font size="-1">8</font></span><span
            style="mso-fareast-language:IT"><o:p></o:p></span></p>
        <span style="font-size:10.0pt;font-family:"Times New
          Roman","serif";mso-fareast-language:IT">Mobile:
          +39 349.800.60.35 <span style="color:black"><br>
            Email: </span><u><span style="color:blue"><a
                href="mailto:ftoffoli@skylogic.it"
                moz-do-not-send="true">ftoffoli@skylogic.it</a></span></u></span><span
          style="font-size:12.0pt;font-family:"Times New
          Roman","serif";color:black;mso-fareast-language:IT"><br>
        </span><b><span style="font-size:12.0pt;font-family:"Times
            New
Roman","serif";color:#000099;mso-fareast-language:IT"><img
              shrinktofit="true" id="_x0000_i1025"
src="imap://ftoffoli@imap.skylogic.it:143/fetch%3EUID%3E/INBOX%3E233968?part=1.2&filename=/home/franz/skylogic_logo.jpeg"
              moz-do-not-send="true" width="190" border="0" height="44"><br>
          </span></b><b><span
            style="font-size:10.0pt;font-family:"Times New
            Roman","serif";color:#000099;mso-fareast-language:IT">Skylogic
            S. p. A.</span></b><span
          style="font-size:10.0pt;font-family:"Times New
          Roman","serif";color:black;mso-fareast-language:IT"><br>
          Strada Pianezza, 289<br>
          10151 Torino, Italy </span> </div>
      <br>
      This message contains confidential information and is intended
      only for the individual named. If you are not the named addressee
      you should not disseminate, distribute or copy this e-mail. Please
      notify the sender immediately by e-mail if you have received this
      e-mail by mistake and delete this e-mail from your system. E-mail
      transmission cannot be guaranteed to be secure or error-free as
      information could be intercepted, corrupted, lost, destroyed,
      arrive late or incomplete, or contain viruses. The sender
      therefore does not accept liability for any errors or omissions in
      the contents of this message, which arise as a result of e-mail
      transmission. If verification is required please request a
      hard-copy version. Please note that any views or opinions
      presented in this email are solely those of the author and do not
      necessarily represent those of the Company.<br>
      No employee or agent is authorized to conclude any binding
      agreement on behalf of this Company nor, through thi s latter, any
      of the Eutelsat Communication group with another party by email
      without express written confirmation by a duly authorized officer
      of the Company. The list of duly authorized officers and the scope
      of their powers is published on the Trade Register according to
      the national law of each affiliate.
      <br>
    </blockquote>
    <br>
    <pre class="moz-signature" cols="72">-- 


Ingby <a class="moz-txt-link-rfc2396E" href="http://www.ingby.com"><http://www.ingby.com></a>

bischeck - dynamic and adaptive monitoring for Nagios <a class="moz-txt-link-rfc2396E" href="http://www.bischeck.org"><http://www.bischeck.org></a>

<a class="moz-txt-link-abbreviated" href="mailto:anders.haal@ingby.com">anders.haal@ingby.com</a><a class="moz-txt-link-rfc2396E" href="mailto:anders.haal@ingby.com"><mailto:anders.haal@ingby.com></a>

Mjukvara genom ingenjörsmässig kreativitet och kompetens

Ingenjörsbyn
Box 531
101 30 Stockholm
Sweden
<a class="moz-txt-link-abbreviated" href="http://www.ingby.com">www.ingby.com</a> <a class="moz-txt-link-rfc2396E" href="http://www.ingby.com/"><http://www.ingby.com/></a>
Mobil: +46 70 575 35 46
Tele: +46 75 75 75 090
Fax:  +46 75 75 75 091
</pre>