Foundry Switches

Subhendu Ghosh sghosh at sghosh.org
Thu Dec 29 05:21:29 CET 2005


On Fri, 2 Dec 2005, Richard Gliebe wrote:

> On Thu, 2005-12-01 at 16:02 +0100, Sébastien Barbereau wrote:
>
> Hi there:
>
>> From the foundry mib file:
>> snChasActualTemperature OBJECT-TYPE
>>     SYNTAX  INTEGER (-110..250)
>>  ACCESS read-only
>>  STATUS mandatory
>>  DESCRIPTION
>>   "Temperature of the chassis. Each unit is 0.5 degrees Celcius. Only
>> management module built with temperature sensor hardware is
>> applicable. For those non-applicable management module, it returns
>> no-such-name."
>>  ::= { snChasGen 18 }
>>
>> So should be 72 is 36°C
>
> I've read this already on http://www.mibdepot.com, but I'm looking for a
> mib, which is showing me the *exact* "°C".
>
> Richard
>

The above mib object give you exactly that - degree Centigrade after you 
multiply by 0.5.

So the temperature granularity is 1/2 C instead of being 1C.

-- 
-sg