<div>Looks like some strange output on the lines for controller 1? The formatting is breaking there. I checked omreport storage controller and didn't see anything that stood out as being strange.</div><div><br></div>
<div> System: PowerEdge 1950 III OMSA version: 6.4.0</div><div> ServiceTag: XXXXXXX Plugin version: 3.6.5</div><div> BIOS/date: 2.7.0 10/30/2010 Checking mode: local</div>
<div>-----------------------------------------------------------------------------</div><div> Storage Components </div><div>=============================================================================</div>
<div> STATE | ID | MESSAGE TEXT </div><div>---------+----------+--------------------------------------------------------</div><div> OK | 0 | Controller 0 [PERC 6/i Integrated] is Ready</div>
<div> OK | 1 | Controller 1 [PERC 6/E Adapter] is Ready</div><div> OK | 0:0:0:0 | Physical Disk 0:0:0 [SAS-HDD 73GB] on ctrl 0 is Online</div><div> OK | 0:0:0:1 | Physical Disk 0:0:1 [SAS-HDD 73GB] on ctrl 0 is Online</div>
<div> OK | 0:0:0:2 | Physical Disk 0:0:2 [SAS-HDD 73GB] on ctrl 0 is Online</div><div> OK | 0:0:0:3 | Physical Disk 0:0:3 [SAS-HDD 73GB] on ctrl 0 is Online</div><div> OK | 1:0:0:0 | Physical Disk 0:0:0 [SAS-HDD 73GB] on ctrl 1 is Online</div>
<div> OK | 1:0:0:1 | Physical Disk 0:0:1 [SAS-HDD 73GB] on ctrl 1 is Online</div><div> OK | 1:0:0:2 | Physical Disk 0:0:2 [SAS-HDD 73GB] on ctrl 1 is Online</div><div> OK | 1:0:0:3 | Physical Disk 0:0:3 [SAS-HDD 73GB] on ctrl 1 is Online</div>
<div> OK | 1:0:0:4 | Physical Disk 0:0:4 [SAS-HDD 73GB] on ctrl 1 is Online</div><div> OK | 1:0:0:5 | Physical Disk 0:0:5 [SAS-HDD 73GB] on ctrl 1 is Online</div><div> OK | 1:0:0:6 | Physical Disk 0:0:6 [SAS-HDD 73GB] on ctrl 1 is Online</div>
<div> OK | 1:0:0:7 | Physical Disk 0:0:7 [SAS-HDD 73GB] on ctrl 1 is Online</div><div> OK | 1:0:0:8 | Physical Disk 0:0:8 [SAS-HDD 73GB] on ctrl 1 is Online</div><div> OK | 1:0:0:9 | Physical Disk 0:0:9 [SAS-HDD 73GB] on ctrl 1 is Online</div>
<div> OK | 1:0:0:10 | Physical Disk 0:0:10 [SAS-HDD 73GB] on ctrl 1 is Online</div><div> OK | 1:0:0:11 | Physical Disk 0:0:11 [SAS-HDD 73GB] on ctrl 1 is Online</div><div> OK | 1:0:0:12 | Physical Disk 0:0:12 [SAS-HDD 73GB] on ctrl 1 is Online</div>
<div> OK | 1:0:0:13 | Physical Disk 0:0:13 [SAS-HDD 73GB] on ctrl 1 is Online</div><div> OK | 1:0:0:14 | Physical Disk 0:0:14 [SAS-HDD 73GB] on ctrl 1 is Online</div><div> OK | 1:0:0:15 | Physical Disk 0:0:15 [SAS-HDD 73GB] on ctrl 1 is Online</div>
<div> OK | 1:0:0:16 | Physical Disk 0:0:16 [SAS-HDD 73GB] on ctrl 1 is Online</div><div> OK | 1:0:0:17 | Physical Disk 0:0:17 [SAS-HDD 73GB] on ctrl 1 is Online</div><div> OK | 1:0:0:18 | Physical Disk 0:0:18 [SAS-HDD 73GB] on ctrl 1 is Online</div>
<div> OK | 1:0:0:19 | Physical Disk 0:0:19 [SAS-HDD 73GB] on ctrl 1 is Online</div><div> OK | 1:0:0:20 | Physical Disk 0:0:20 [SAS-HDD 73GB] on ctrl 1 is Online</div><div> OK | 1:0:0:21 | Physical Disk 0:0:21 [SAS-HDD 73GB] on ctrl 1 is Online</div>
<div> OK | 1:0:0:22 | Physical Disk 0:0:22 [SAS-HDD 73GB] on ctrl 1 is Online</div><div> OK | 1:0:0:23 | Physical Disk 0:0:23 [SAS-HDD 73GB] on ctrl 1 is Ready (Dedicated HS)</div><div> OK | 0:0 | Logical Drive 'Windows Disk 0' [RAID-6, 135.50 GB] is Ready</div>
<div> OK | 1:0 | Logical Drive 'Windows Disk 1' [RAID-6, 1,422.75 GB] is Ready</div><div> OK | 0:0 | Cache Battery 0 in controller 0 is Ready</div><div> OK | 1:0 | Cache Battery 0 in controller 1 is Ready</div>
<div> OK | 0:0 | Connector 0 [SAS Port RAID Mode] on controller 0 is Ready</div><div> OK | 0:1 | Connector 1 [SAS Port RAID Mode] on controller 0 is Ready</div><div> OK | 1:0 | Logical Connector [SAS Port RAID Mode] on controller 1 is Ready</div>
<div> | 1:Status | State [Name] on controller 1 is Status</div><div> | 1:Ok | Available [Unknown type] on controller 1 is Unknown state</div><div> | 1:Ok | Available [Unknown type] on controller 1 is Unknown state</div>
<div> OK | 0:0:0 | Enclosure 0:0:0 [Backplane] on controller 0 is Ready</div><div> OK | 1:0:0 | Enclosure 1:0:0 [MD1120] on controller 1 is Ready</div><div> OK | 1:0:0:1 | Fan 1 in enclosure 1:0:0 [MD1120] is Ready (speed=Slow)</div>
<div> OK | 1:0:0:2 | Fan 2 in enclosure 1:0:0 [MD1120] is Ready (speed=Slow)</div><div> OK | 1:0:0:3 | Fan 3 in enclosure 1:0:0 [MD1120] is Ready (speed=Slow)</div><div> OK | 1:0:0:4 | Fan 4 in enclosure 1:0:0 [MD1120] is Ready (speed=Slow)</div>
<div> OK | 1:0:0:5 | Fan 5 in enclosure 1:0:0 [MD1120] is Ready (speed=Slow)</div><div> OK | 1:0:0:6 | Fan 6 in enclosure 1:0:0 [MD1120] is Ready (speed=Slow)</div><div> OK | 1:0:0:7 | Fan 7 in enclosure 1:0:0 [MD1120] is Ready (speed=Slow)</div>
<div> OK | 1:0:0:8 | Fan 8 in enclosure 1:0:0 [MD1120] is Ready (speed=Slow)</div><div> OK | 1:0:0:1 | Power Supply 1 in enclosure 1:0:0 [MD1120] is Ready</div><div> OK | 1:0:0:2 | Power Supply 2 in enclosure 1:0:0 [MD1120] is Ready</div>
<div> OK | 1:0:0:0 | Temperature Probe 0 in enclosure 1:0:0 [MD1120] reads 25 C (min=-2/-2, max=65/65)</div><div> OK | 1:0:0:1 | Temperature Probe 1 in enclosure 1:0:0 [MD1120] reads 23 C (min=-2/-2, max=65/65)</div>
<div> OK | 1:0:0:2 | Temperature Probe 2 in enclosure 1:0:0 [MD1120] reads 19 C (min=8/3, max=50/55)</div><div> OK | 1:0:0:3 | Temperature Probe 3 in enclosure 1:0:0 [MD1120] reads 21 C (min=8/3, max=50/55)</div>
<div> OK | 1:0:0:0 | EMM 0 in enclosure 1:0:0 [MD1120] is Ready</div><div> OK | 1:0:0:1 | EMM 1 in enclosure 1:0:0 [MD1120] is Ready</div><div>-----------------------------------------------------------------------------</div>
<div> Chassis Components </div><div>=============================================================================</div><div> STATE | ID | MESSAGE TEXT </div>
<div>---------+------+------------------------------------------------------------</div><div> OK | 0 | Memory module 0 [DIMM1, 2048 MB] is Ok</div><div> OK | 1 | Memory module 1 [DIMM2, 2048 MB] is Ok</div>
<div> OK | 2 | Memory module 2 [DIMM3, 2048 MB] is Ok</div><div> OK | 3 | Memory module 3 [DIMM4, 2048 MB] is Ok</div><div> OK | 0 | Chassis fan 0 [System Board FAN MOD 1A RPM]: 7050</div><div> OK | 1 | Chassis fan 1 [System Board FAN MOD 1B RPM]: 7125</div>
<div> OK | 2 | Chassis fan 2 [System Board FAN MOD 1C RPM]: 4650</div><div> OK | 3 | Chassis fan 3 [System Board FAN MOD 1D RPM]: 4500</div><div> OK | 4 | Chassis fan 4 [System Board FAN MOD 2A RPM]: 7050</div>
<div> OK | 5 | Chassis fan 5 [System Board FAN MOD 2B RPM]: 7275</div><div> OK | 6 | Chassis fan 6 [System Board FAN MOD 2C RPM]: 4575</div><div> OK | 7 | Chassis fan 7 [System Board FAN MOD 2D RPM]: 4500</div>
<div> OK | 8 | Chassis fan 8 [System Board FAN MOD 3A RPM]: 7500</div><div> OK | 9 | Chassis fan 9 [System Board FAN MOD 3B RPM]: 7500</div><div> OK | 10 | Chassis fan 10 [System Board FAN MOD 3C RPM]: 4725</div>
<div> OK | 11 | Chassis fan 11 [System Board FAN MOD 3D RPM]: 4650</div><div> OK | 12 | Chassis fan 12 [System Board FAN MOD 4A RPM]: 7350</div><div> OK | 13 | Chassis fan 13 [System Board FAN MOD 4B RPM]: 7200</div>
<div> OK | 14 | Chassis fan 14 [System Board FAN MOD 4C RPM]: 4575</div><div> OK | 15 | Chassis fan 15 [System Board FAN MOD 4D RPM]: 4725</div><div> OK | 0 | Power Supply 0 [AC]: Presence Detected</div>
<div> OK | 1 | Power Supply 1 [AC]: Presence Detected</div><div> OK | 0 | Temperature Probe 0 [System Board Ambient Temp] reads 14 C (min=8/3, max=42/47)</div><div> OK | 0 | Processor 0 [Intel Xeon E5430 2.66GHz] is Present</div>
<div> OK | 1 | Processor 1 [Intel Xeon E5430 2.66GHz] is Present</div><div> OK | 0 | Voltage sensor 0 [CPU1 VCORE] is Good</div><div> OK | 1 | Voltage sensor 1 [CPU2 VCORE] is Good</div><div> OK | 2 | Voltage sensor 2 [System Board CPU VTT] is Good</div>
<div> OK | 3 | Voltage sensor 3 [System Board 1.5V PG] is Good</div><div> OK | 4 | Voltage sensor 4 [System Board 1.8V PG] is Good</div><div> OK | 5 | Voltage sensor 5 [System Board 3.3V PG] is Good</div>
<div> OK | 6 | Voltage sensor 6 [System Board 5V PG] is Good</div><div> OK | 7 | Voltage sensor 7 [Riser 1.5V PXH PG] is Good</div><div> OK | 8 | Voltage sensor 8 [Riser 5V Riser PG] is Good</div><div>
OK | 9 | Voltage sensor 9 [System Board Backplane PG] is Good</div><div> OK | 10 | Voltage sensor 10 [System Board Linear PG] is Good</div><div> OK | 11 | Voltage sensor 11 [System Board 0.9V PG] is Good</div>
<div> OK | 12 | Voltage sensor 12 [System Board 0.9V Over Volt] is Good</div><div> OK | 13 | Voltage sensor 13 [System Board CPU Power Fault] is Good</div><div> OK | 0 | Battery probe 0 [System Board CMOS Battery] is Good</div>
<div> OK | 0 | Chassis intrusion 0 detection: Ok (Chassis is closed)</div><div>-----------------------------------------------------------------------------</div><div> Other messages </div>
<div>=============================================================================</div><div> STATE | MESSAGE TEXT </div><div>---------+-------------------------------------------------------------------</div>
<div> OK | ESM log health is Ok (less than 80% full)</div><div><br/>INTERNAL ERROR: Use of uninitialized value $level in hash element at script/check_openmanage line 4599.<br/>INTERNAL ERROR: Use of uninitialized value within %reverse_exitcode in subtraction (-) at script/check_openmanage line 4599.<br/>INTERNAL ERROR: Use of uninitialized value $level in hash element at script/check_openmanage line 4599.<br/>INTERNAL ERROR: Use of uninitialized value within %reverse_exitcode in concatenation (.) or string at script/check_openmanage line 4599.<br/>INTERNAL ERROR: Use of uninitialized value $level in hash element at script/check_openmanage line 4601.<br/>INTERNAL ERROR: Use of uninitialized value within %reverse_exitcode in hash element at script/check_openmanage line 4601.<br/>INTERNAL ERROR: Use of uninitialized value $level in hash element at script/check_openmanage line 4599.<br/>INTERNAL ERROR: Use of uninitialized value within %reverse_exitcode in subtraction (-) at script/check_openmanage line 4599.<br/>INTERNAL ERROR: Use of uninitialized value $level in hash element at script/check_openmanage line 4599.<br/>INTERNAL ERROR: Use of uninitialized value within %reverse_exitcode in concatenation (.) or string at script/check_openmanage line 4599.<br/>INTERNAL ERROR: Use of uninitialized value $level in hash element at script/check_openmanage line 4601.<br/>INTERNAL ERROR: Use of uninitialized value within %reverse_exitcode in hash element at script/check_openmanage line 4601.<br/>INTERNAL ERROR: Use of uninitialized value $level in hash element at script/check_openmanage line 4599.<br/>INTERNAL ERROR: Use of uninitialized value within %reverse_exitcode in subtraction (-) at script/check_openmanage line 4599.<br/>INTERNAL ERROR: Use of uninitialized value $level in hash element at script/check_openmanage line 4599.<br/>INTERNAL ERROR: Use of uninitialized value within %reverse_exitcode in concatenation (.) or string at script/check_openmanage line 4599.<br/>INTERNAL ERROR: Use of uninitialized value $level in hash element at script/check_openmanage line 4601.<br/>INTERNAL ERROR: Use of uninitialized value within %reverse_exitcode in hash element at script/check_openmanage line 4601.</div>