No alerts/notifications ?

Brian Ipsen Brian.Ipsen-sender-25cac0 at andebakken.dk
Fri Jun 13 12:19:19 CEST 2003


Hi!

 I have a wierd problem..... A host has been defines as:

define host{
        use                     generic-host            ; Name of host
template to use

        host_name               3-sal-vest-ekstra
        alias                   Printer #7
        address                 192.168.116.223
        check_command           check-host-alive
        parents                 Switch-Master
        max_check_attempts      10
        notification_interval   480
        notification_period     workhours
        }

With services:

define service{
        use                             generic-service         ; Name of
service template to use

        host_name                       3-sal-vest-ekstra
        service_description             PING
        is_volatile                     0
        check_period                    24x7
        max_check_attempts              3
        normal_check_interval           5
        retry_check_interval            1
        contact_groups                  printer-admins
        notification_interval           120
        notification_period             workhours
        notification_options            c,r
        check_command                   check_ping!100.0,20%!500.0,60%
        }

define service{
        use                             generic-service         ; Name of
service template to use

        host_name                       3-sal-vest-ekstra
        service_description             Printer Status
        is_volatile                     0
        check_period                    24x7
        max_check_attempts              3
        normal_check_interval           5
        retry_check_interval            1
        contact_groups                  printer-admins
        notification_interval           120
        notification_period             24x7
        notification_options            c,r
        check_command                   check_hpjd
        }

Powering off the device, and leaving it off for 40 minutes gives:

3-sal-vest-ekstra	PING  	   CRITICAL 13-06-2003 12:11:06 0d 0h 40m 51s 1/3
CRITICAL - Plugin timed out after 10 seconds
			Printer Status CRITICAL 13-06-2003 12:07:47 0d 0h 40m 11s 1/3 Timeout: No
response from 192.168.116.223

But no notifications ??? Is this because of the notification interval of 480
minutes ?? The history of the device on the log is:

[13-06-2003 11:47:56] HOST ALERT: 3-sal-vest-ekstra;DOWN;HARD;10;CRITICAL -
Plugin timed out after 10 seconds
[13-06-2003 11:46:26] HOST ALERT: 3-sal-vest-ekstra;DOWN;HARD;10;CRITICAL -
Plugin timed out after 10 seconds
[13-06-2003 11:45:46] Finished daemonizing... (New PID=14658)
[13-06-2003 11:45:46] Nagios 1.0 starting... (PID=14657)
[13-06-2003 11:45:46] Successfully shutdown... (PID=12939)
[13-06-2003 11:45:46] Caught SIGTERM, shutting down...
[13-06-2003 11:32:25] SERVICE ALERT: 3-sal-vest-ekstra;Printer
Status;CRITICAL;HARD;1;Timeout: No response from 192.168.116.223
[13-06-2003 11:31:45] SERVICE ALERT:
3-sal-vest-ekstra;PING;CRITICAL;HARD;1;TEST
[13-06-2003 11:31:45] HOST ALERT: 3-sal-vest-ekstra;DOWN;HARD;10;CRITICAL -
Plugin timed out after 10 seconds
[13-06-2003 11:31:35] HOST ALERT: 3-sal-vest-ekstra;DOWN;SOFT;9;CRITICAL -
Plugin timed out after 10 seconds
[13-06-2003 11:31:25] HOST ALERT: 3-sal-vest-ekstra;DOWN;SOFT;8;CRITICAL -
Plugin timed out after 10 seconds
[13-06-2003 11:31:15] HOST ALERT: 3-sal-vest-ekstra;DOWN;SOFT;7;CRITICAL -
Plugin timed out after 10 seconds
[13-06-2003 11:31:05] HOST ALERT: 3-sal-vest-ekstra;DOWN;SOFT;6;CRITICAL -
Plugin timed out after 10 seconds
[13-06-2003 11:30:55] HOST ALERT: 3-sal-vest-ekstra;DOWN;SOFT;5;CRITICAL -
Plugin timed out after 10 seconds
[13-06-2003 11:30:45] HOST ALERT: 3-sal-vest-ekstra;DOWN;SOFT;4;CRITICAL -
Plugin timed out after 10 seconds
[13-06-2003 11:30:35] HOST ALERT: 3-sal-vest-ekstra;DOWN;SOFT;3;CRITICAL -
Plugin timed out after 10 seconds
[13-06-2003 11:30:25] HOST ALERT: 3-sal-vest-ekstra;DOWN;SOFT;2;CRITICAL -
Plugin timed out after 10 seconds
[13-06-2003 11:30:15] HOST ALERT: 3-sal-vest-ekstra;DOWN;SOFT;1;CRITICAL -
Plugin timed out after 10 seconds
[13-06-2003 11:22:25] SERVICE ALERT: 3-sal-vest-ekstra;Printer
Status;OK;HARD;1;Printer ok - (STRING: "Ready --- A4 PLAIN ")

Any ideas to why no notifications isn't sent ?


Regards,

/Brian


-------------------------------------------------------
This SF.NET email is sponsored by: eBay
Great deals on office technology -- on eBay now! Click here:
http://adfarm.mediaplex.com/ad/ck/711-11697-6916-5
_______________________________________________